Effect of Carbon Content on the Microstructure and Mechanical Properties of Hyness 25 Superalloy

Document Type : Original Research Article

Authors

1 M.Sc., Materials Department, Malek Ashtar University of Technology, Tehran, IRAN.‎

2 Assistant Professor, Materials Department, Malek Ashtar University of Technology, Tehran, IRAN.‎

3 Professor, Materials Department, Malek Ashtar University of Technology, Tehran, IRAN.‎

10.22034/frj.2020.245305.1126

Abstract

The effects of 0.05, 0.1 and 0.15 wt% C on the microstructure, hardness and tensile properties of annealed Haynes 25 were investigated. The alloys were melted in a vacuum induction melting furnace and purified through electro slag remelting process then solution annealed at 1200˚C for 30 min. The results indicated that W-riched M6C carbides developed in the microstructure and its amount increase with increase of carbon. By increase of Carbon from 0.05 to 0.15wt%, grain size decrease from 44 to 35 µm. The carbides act as nucleator and also retard grain growth that cause to reduce grain size. Mechanical properties investigation shows that with increasing carbon, as a result of grain refinement and the proper size and morphology of carbides, hardness increases from 255 to 290 Hv, yield strength from 450 to 510 MPa and ultimate tensile strength from 946 to 1088 MPa but ductility decreases slightly.

Keywords

Main Subjects


[1]  Donachie M.J., Donachie S.J., Superalloys: a technical guide: ASM international, 2002.
[2]  Lee S., Liaw P.K., High-temperature tensile-hold crack-growth behavior of Hastelloy X alloy compared to Haynes 188 and Haynes 230 alloys, Mechanics of Time-Dependent Materials, 2008, 12, 31-44.
[3]  Favre J., Koizumi Y., Deformation behavior and dynamic recrystallization of biomedical Co-Cr-W-Ni (L-605) alloy, Metallurgical and Materials Transactions A, 2013, 44, 2819-2830.
[4]  Mori M., Effect of cold rolling on phase decomposition in biomedical Co–29Cr–6Mo–0.2 N alloy during isothermal heat treatment at 1073 K, Journal of Alloys and Compounds, 2014, 612, 273-279.
[5]  Klarstrom D., Wrought cobalt-base superalloys, Journal of Materials Engineering and Performance, 1993, 2, 523-530.
[6]  Tawancy H., Ishwar V.R., Lewis B.E., On the fcc→ hcp transformation in a cobalt-base superalloy (Haynes alloy No. 25), Journal of Materials Science Letters, 1986, 5, 337-341.
[7]  Jiang W., Guan H.R., Secondary carbide precipitation in a directionally solified cobalt-base superalloy, Metallurgical and Materials Transactions, 1999, 30, 513-520.
[8]  Pu S., Zhang J., Recrystallization in a directionally solidified cobalt-base superalloy, Materials Science and Engineering: A, 2008, 480, 428-433.
[9]  Ueki K., Ueda K., Microstructure and Mechanical Properties of Heat-Treated Co-20Cr-15W-10Ni Alloy for Biomedical Application, Metallurgical and Materials Transactions A, 2016, 47, 2773-2782.
[10] Inoue A., Masumoto T., Carbide reactions (M3C→ M7C3→ M23C6→ M6C) during tempering of rapidly solidified high carbon Cr-W and Cr-Mo steels, Metallurgical and Materials Transactions A, 1980, 11, 739-747.
[11] Huron E.S., Leon H., Superalloy, John Wiley & Sons, 2012.
[12] Yukawa N., Sato K., Correlation between microstructure and stress rupture properties of A Co--Cr--Ni--W (HS-25) alloy, 1968, Nagoya Univ., Japan.
[13] Gui W., zhang H., The investigation of carbides evolution in a cobalt-base superalloy at elevated temperature, Journal of Alloys and Compounds, 2017, 695, 1271-1278.
[14] Sorensen D., Mokhoyan K.A., Investigation of secondary hardening in Co–35Ni–20Cr–10Mo alloy using analytical scanning transmission electron microscopy, Acta Materialia, 2014, 63, 63-72.
[15] Lee S. H., Effect of carbon addition on microstructure and mechanical properties of a wrought Co-Cr-Mo implant alloy, Materials transactions, 2006, 47, 287-290.
[16] Yamanaka K., Mori M., Development of new Co–Cr–W-based biomedical alloys: effects of microalloying and thermomechanical processing on microstructures and mechanical properties, Materials & Design, 2014, 55, 987-998.
[17] Wu X., Liu R., Yao M., Influence of carbon content in cobalt based superalloys on mechanical and wear properties, Journal of Engineering Materials and Technology, 2004, 126, 204-212.
[18] F90-01: Standard Specification for Wrought Cobalt-20Chromium-15Tungsten-10Nickel Alloy for Surgical Implant Applications (UNS R30605), ASTM International, West Conshohocken, 2005.
[19] ASTM E 8M, Standard test methods of tension testing of metallic materials [metric], Annual Book of ASTM Standards Vol. 3, ed., 2003.
[20] ASTM E 92, Standard Test Method for Vickers Hardness of Metallic Materials, Vol. 2, West Conshohocken, PA: ASTM International, 2003.
[21] Yamanaka K., Mori M., Chiba A., Influence of carbon addition on mechanical properties and microstructures of Ni-free Co–Cr–W alloys subjected to thermomechanical processing, Journal of the Mechanical Behavior of Biomedical Materials, 2014, 37, 274-285.
[22] Mori M., Yammanaka K., Effect of carbon on the microstructure, mechanical properties and metal ion release of Ni-free Co–Cr–Mo alloys containing nitrogen, Materials Science and Engineering: C, 2015, 55, 145-154.
[23] Yamanaka K., Chiba A., Effects of carbon concentration on microstructure and mechanical properties of as-cast nickel-free Co–28Cr–9W-based dental alloys, Materials Science and Engineering: C, 2014, 40, 127-134.
[24] Teague J., cerreta E., Tensile properties and microstructure of Haynes 25 alloy after aging at elevated temperatures for extended times, Metallurgical and Materials Transactions A, 2004, 35, 2767-2781.
[25] Joseph C., Influence of heat treatment on the microstructure and tensile properties of Ni-base superalloy Haynes 282, Materials Science and Engineering: A, 2017, 679, 520-530.